ANEST IWATA oil free air compressor
| |
 |
|
 |
 |
 |
 |
 |
 |
Oil-Tank 0.75~11kW | |
 |
Oil-Package 0.75~11kW | |
 |
Oil free-Tank 0.75~11kW | |
 |
Oil free-Package 0.75~11kW | |
 |
 |
Oil/Anti-dust filter/Air transformer | | |
 |
 |
 |
 |
SmartAir series 0.75~3.7kW | |
 |
SLP-C series 5.5~30kW | | |
 |
 |
 |
 |
SCD-K series 7.5~11kW |
|
 |
SCD-JC series 11~75kW 55~75kW | |
 |
 |
| · |
Pressure switch type offers simple control. |
| · |
More reasonable prices in comparison with previous TLD series . |
| · |
"COMG" oil-lubricating type provides easier and more economical operation. |
|
 |
|
*Some models may not be available for sales in certain countries.
|
|
|
|
COMG embodies the high standards in basic performance, durability, safety and versatility. | |
| · |
All models are equipped with totally-enclosed motors which prevent motor problems such as damage to bearings by dust or insulation deterioration by moisture. |
| · |
Rotating sections are covered by a totally-enclosed belt guard. |
High performance for professional use |
| · |
Two-way cooling system effectively releases compression heat (for 2.2kW and above). |
|
 |
Specifications of lubricating type-tank-mounted |
 |
 | |
0.75kW/1.5kW/2.2kW |
|
Model |
| Item |
TLPC07-10 |
TLP15-10 |
TLP22B-10 |
TLP22B-14 |
Motor rated output (kW{PS}) |
0.75{1} |
1.5{2} |
2.2{3} |
Operation control system
|
pressure switch |
Control pressure (MPa) |
0.8 1.0 |
1.15 1.4 |
Free air delivery (L/min) |
75 |
165 |
255 |
235 |
Air receiver capacity (L) |
39 |
70 |
80 |
165 |
Air outlet (B) |
G 1/4×1 ball cock |
G 1/4×2 ball cock |
Rc 3/4×1 ball valve G 1/4×1 ball cock |
Rotating speed (min-1(rpm)) |
1150 |
1240 |
1025 |
920 |
Extenal dimensions ((W×L×H)(mm)) |
760× 350×690 |
1065× 385×800 |
1200× 425×840 |
1430× 475×990 |
Mass (kg) |
48 |
77 |
98 |
145 |
Noise level(1.5m from front) (dB(A)) |
69 |
70 |
| Oil alarm |
- |
Option (POA-225) |
Option (POA-225) |
3.7kW/5.5kW |

|
Model |
| Item |
TLP37B-10 |
TLP37B-14 |
TLP55B-10 |
TLP55B-14 |
Motor rated output (kW{PS}) |
3.7{5} |
5.5{7.5} |
Operation control system
|
pressure switch |
Control pressure (MPa) |
0.8  1.0 |
1.15  1.4 |
0.8  1.0 |
1.15  1.4 |
Free air delivery (L/min) |
400 |
390 |
630 |
590 |
Air receiver capacity (L) |
120 |
220 |
165 |
220 |
Air outlet (B) |
Rc 3/4×1 ball valve & G 1/4×1 ball cock |
Rotating speed (min-1(rpm)) |
1050 |
1100 |
1110 |
1010 |
External dimensions ((W×L×H)(mm)) |
1400× 450×955 |
1500× 550×1080 |
1430× 530×1040 |
1500× 550×1080 |
Mass (kg) |
139 |
165 |
198 |
202 |
Noise level(1.5m from front) (dB(A)) |
73 |
71 |
72 |
| Oil alarm |
Option(POA-225) |
Option(POA-223) |
7.5kW/11kW |
|
Model |
| Item |
TLP75B-10 |
TLP75B-14 |
TLP110B-10 |
TLP110B-14 |
Motor rated output (kW{PS}) |
7.5{10} |
11{15} |
Operation control system
|
pressure switch |
Control pressure (MPa) |
0.8 1.0 |
1.15 1.4 |
0.8 1.0 |
1.15 1.4 |
Free air delivery (L/min) |
855 |
755 |
1285 |
1125 |
Air receiver capacity (L) |
220 |
250 |
Air outlet (B) |
Rc 3/4×1 ball valve & G 1/4×1 ball cock |
Rotating speed (min-1(rpm)) |
960 |
860 |
1110 |
970 |
External dimensions ((W×L×H)(mm)) |
1500×580×1110 |
1685×580×1110 |
Mass (kg) |
245 |
293 |
Noise level(1.5m from front) (dB(A)) |
74 |
77 |
| Oil alarm |
Option(POA-223) |
| * |
1. |
Air delivery means average discharge air volume at max. operating pressure which is converted into atmospheric pressure. It is not a warranted figure. Specific warranted figure will be available upon request. |
| * |
2. |
Noise level is measured in an anechoic room during full-load operation. | | |
 |
 |
 |
 |
 |
|
*Some models may not be available for sales in certain countries. |
 |
Load and unloaded control of highly efficient energy-saving effect. |
 |
 | |
| ·Loaded and unloaded control is an automatic control function. Loaded control generates air at 100% of capacity while unloaded control does not generate air at all. As electric consumption during unloaded control is about 25% of that used during loaded control, you can get a high energy-saving effect. For example, compared with an intake throttle valve, you can obtain an energy-saving effect of about 25% when the air consumption rate is 50%. |
 |
A very large free air delivery in the screw compressor field |
| · |
Large free air delivery means it takes less time to generate the same air volume, thereby lowering electricity cost. |
You can change pressure quickly. |
| · |
Generally, control pressure difference is 0.1MPa, but standard control pressure difference of SCD-J is 0.06MPa. You can change control pressure difference in units of 0.01MPa. If you decrease max. pressure by 0.05MPa, you can obtain a 3.5% energy savings. (When you make pressure difference smaller, select proper size of air receiver.) |
 |
11kW and above are direct-coupled type. |
| · |
We have deleted V belts from 11kW and above. This eliminates loss due to V belt slippage and enhances energy savings. |
|
|
|
We have adopted new refrigeration system with a zero ozone depletion factor. |
| · |
SCD-J series with built-in air dryers have adopted new refrigerant HFC134a/HFC404a with zero ozone depletion factor since its sales launch in 1999. |
 |
Oil content in exhaust air is only 0.0025cm3/m3. |
| · |
Anest Iwata pays great attention to oil content since it manufactures and sells painting equipment. Oil content in exhaust air is 0.0025cm3/m3(0.0031cm3/m3 for only 30~45kW), about half that of common screw compressors on the market |
CD-110JC/150JC/220JC are gear direct coupled type. |
| · |
V belts and couplings become obsolete. |
|
|
|
All rotors are metallic. |
| · |
As air end has metallic rotors, there is almost no air volume loss due to rotor wear. 110JC~450JC type is equipped with phase sequence protection function. |
 | |
All models are equipped with dustproof motors as standard specifications. |
| · |
Main motors are IP55 class dustproof motors and fan motors are IP54 class dustproof motors as standard specifications. We have confidence in reliability even under severe conditions. *IP55/54 are motor protection class designated by JISC4034-5. |
 | |
Comes equipped with high quality intake filter (excluding K type of 11kW and above). |
| · |
| High quality filter can trap 99.9% of particles with a dia. of 3µm. In case of 30kW and above, dust is trapped through two stages of "centrifugal separation+filtering separation". |
 | |
|
|
|
Daily maintenance is possible from the front. |
| · |
You can do the daily maintenance from the front, including confirmation of oil level, oil refilling, inspection of intake filter and blowing cooler with air. |
|
Cutting-edge electronics systems are used. |
| · |
Group control function is added. You can control a maximum of four sets with optional plug and cable. Also change setting pressure according to the day of the week and time, resulting in reduction in electric consumption. |
| · |
Two kinds of pressure ranges can be set. Manual changeover, time changeover, simple alternate operation up to four sets become possible. You can also change setting pressure according to the day of the week and time, resulting in reduction in electric consumption. |
| · |
It can automatically select loaded or unloaded operation or automatic stop operation in accordance with air consumption. It automatically changes to loaded operation in advance considering the necessary time it takes pressure to drop so that pressure does not drop below setting pressure. |
| · |
Setting pressure can be easily changed by digital display. (When you change pressure difference, please select proper size of air receiver). |
| · |
Automatic restart function after power failure, weekly timer, remote control and automatic operation by external pressure switch are built in as standard equipment. |
| · |
Display monitor displays present operating conditions, required maintenance content, caution, emergency stop and external signal output as standard functions. |
| · |
It records history of past emergency stops which you can confirm on the panel. |
| |
| |
 |
Specifications of medium-sized main line filters AF series |
 |
 | |
| |
Model |
| Item |
SCD-110JC <SCD-1101JC> «SCD-1102JC» |
SCD-110JCD <SCD-1101JCD> «SCD-1102JCD» |
Compressor set |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air, atmospheric pressure 0 40°C (built-in dryer type: air, atmospheric pressure, 2 40°C) |
air delivery *1 (m3/min) |
1.9<1.5>«1.2» |
| driving system |
gear direct coupling |
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
intake temp.+10 or less (built-in dryer type: intake temp.+5 or less) |
air outlet dia. (B) |
1 |
lube oil capacity (L) |
7 |
noise level *2 (dB(A)) |
58 |
Compressor motor |
start-up system |
magnetic star-delta (3 contactors) |
| type *4 |
flange horizontal, TEFC dustproof, 3-phase, 2-pole, F-class insulation,IP55 |
motor rated output *5 (kW) |
11 (service factor 1.2) |
| Fan motor |
type *4 |
TEFC dustproof, 3-phase, 4-pole·F class insulation, IP54 |
motor rated output (kW) |
0.48/0.50 |
Refrigerated dryer |
outlet air dew point *6 (°C) |
- |
10 or less (under pressure) |
electric consumption (kW) |
- |
0.69 |
| refrigerant |
- |
HFC134a |
Outer dimensions *7 ((W×L×H)(mm)) |
1225×650×1400 |
Mass (with oil) (kg) |
400 |
445 | | |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7 (0.95) «1.25» Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7 Mpa during full-load operation. |
| *4. |
IP55 means class of dustproof and waterproof performance based on JIS standard (C4034-5). |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *8. |
Please select air receiver capacity of 400 liters and above. |
| *9. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. |
| |
Model |
| Item |
SCD-150JC *1 <SCD-1501JC> «SCD-1502JC» |
SCD-150JCD *1 <SCD-1501JCD> «SCD-1502JCD» |
Compressor set |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air, atmospheric pressure 0 40°C (built-in dryer type: air, atmospheric pressure, 2 40°C) |
air delivery *1 (m3/min) |
2.7<2.2>«1.8» |
| driving system |
gear direct coupling |
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
intake temp.+10 or less (built-in dryer type: intake temp.+5 or less) |
air outlet dia. (B) |
1 |
lube oil capacity (L) |
7 |
noise level *2 (dB(A)) |
59 |
| Main motor |
start-up system |
magnetic star-delta (3 contactors) |
| type *4 |
flange horizontal, TEFC dustproof, 3-phase, 2-pole, F-class insulation, |
motor rated output *5 (kW) |
11 (service factor 1.2) |
| Fan motor |
type *4 |
TEFC dustproof, 3-phase, 4-pole·F class insulation, IP54 |
motor rated output (kW) |
0.48 / 0.50 |
Refrigerated dryer |
outlet air dew point *6 (°C) |
- |
10 or less (under pressure) |
electric consumption (kW) |
- |
0.69 |
| refrigerant |
- |
HFC134a |
Outer dimensions *7 ((W×L×H)(mm)) |
1225×650×1400 |
Mass (with oil) (kg) |
410 |
475 |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7(0.95)«1.25»Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7Mpa during full-loaded operation. |
| *4. |
IP55·IP54 means class of dustproof and waterproof performance based on JIS standard(C4034-5) |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *8. |
Please select air receiver capacity of 400 liters and above. |
| *9. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. |
| |
Model |
| Item |
SCD-220JC <SCD-2201JC> «SCD-2202JC» |
SCD-220JCD <SCD-2201JCD> «SCD-2202JCD» |
| Compressor |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air, atmospheric pressure 2 40°C |
air, atmospheric pressure 0  40°C |
air delivery *1 (m3/min) |
3.8<3.2>«2.8» |
| driving system |
gear direct coupling |
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
intake temp.+10 or less
(built-in dryer type: intake temp.+5 or less) |
air outlet dia. (B) |
1 |
lube oil capacity (L) |
8 |
noise level *2 (dB(A)) |
60 |
| Main motor |
start-up system |
magnetic star-delta (3 contactors) |
| type *4 |
flange horizontal, TEFC dustproof, 3-phase, 2-pole, F-class insulation,IP55 |
motor rated output *5 (kW) |
11 (service factor 1.2) |
| Fan motor |
motor rated output (kW) |
0.48 / 0.50 |
Refrigerated dryer |
outlet air dew point *6 (°C) |
- |
10 or less (under pressure) |
electric consumption (kW) |
- |
1.0 |
| refrigerant |
- |
HFC134a |
Outer dimensions ((W×L×H)(mm)) |
1225×650×1400 |
Mass (with oil) (kg) |
435 |
500 |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7 (0.95) «1.25» Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7Mpa during full-load operation. |
| *4. |
IP55 means class of dustproof and waterproof performance based on JIS standard (C4034-5). |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *8. |
Please select air receiver capacity of 600 liters and above. |
| *9. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. |
| |
Model |
| Item |
SCD-300JC *1 <SCD-3001JC> «SCD-3002JC» |
SCD-300JCD *1 <SCD-3001JCD> «SCD-3002JCD» |
| Compressor |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air, atmospheric pressure 2 40°C |
air, atmospheric pressure 0 40°C |
air delivery *2 (m3/min) |
5. 6<4.6>«3.8» |
| driving system |
Direct coupling+gear (in case of 50 Hz for SCD-300JC(D) there is no gear) |
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
Intake temp 10°C or less |
intake temp 5°C or less |
air outlet dia. (B) |
1 1 /2 |
lube oil capacity (L) |
14.6 |
noise level *3 (dB(A)) |
62 |
| Main motor |
start-up system |
magnetic star-delta (3 contactors) |
| type *5 |
flange horizontal TEFC dustproof, 3 phase, 2 pole, F-class insulation ,IP55 |
motor rated *6 (kW) |
30 (service factor 1.15) |
| Fan motor |
type *5 |
TEFC, 3 phase, 6 pole, F insulation, IP54 |
motor rated output (kW) |
1.0 / 0.98 |
Refrigerated dryer |
outlet air dew point *7 (°C) |
- |
10 and less (under pressure) |
electric consumption (kW) |
- |
1.6 / 2.1 |
| refrigerant |
- |
HFC404a |
Outer dimensions *7 ((W×L×H)(mm)) |
1713×903×1670 |
Mass(with oil) (kg) |
871 |
1018 |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7 (0.95) «1.25» Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7Mpa during full-load operation. |
| *4. |
IP55 means class of dustproof and waterproof performance based on JIS standard (C4034-5). |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *8. |
Please select air receiver capacity of 1000 liters and above. |
| *9. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. |
| |
Model |
| Item |
SCD-370JC <SCD-3701JC> «SCD-3702JC» |
SCD-370JCD <SCD-3701JCD> «SCD-3702JCD» |
| Compressor |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air,atmospheric pressure 0 40°C |
air,atmospheric pressure 2 40°C |
air delivery *1 (m3/min) |
6.9<5.7>«4.6» |
| driving system |
|
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
intake temp 9°C or less |
intake temp 5°C or less |
air outlet dia. (B) |
1 1/2 |
lube oil capacity (L) |
16.3 |
noise level *2 (dB(A)) |
63 |
| Main motor |
start-up system |
magnetic star-delta (3 contactors) |
| type *4 |
flange horizontal, TEFC, 3 phase, 2 pole, F-class insulation, IP55, grease supply system |
motor rated (kW) |
30 (service factor 1.15) |
| Fan motor |
motor rated output (kW) |
1.0 / 0.98 |
Refrigerated dryer |
outlet air dew point (°C) |
- |
10 or less (under pressure) |
electric consumption (kW) |
- |
2.1/2.5 |
| refrigerant |
- |
HFC404a |
Outer dimensions *7 ((W×L×H)(mm)) |
1713×903×1670 |
Mass (with oil) (kg) |
969 |
1093 |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7 (0.95) «1.25» Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7Mpa during full-load operation. |
| *4. |
IP55 means class of dustproof and waterproof performance based on JIS standard (C4034-5). |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *8. |
Please select air receiver capacity of 1000 liters and above. |
| *9. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. |
| |
Model |
| Item |
SCD-450JC <SCD-4501JC> «SCD-4502JC» |
SCD-450JCD <SCD-4501JCD> «SCD-4502JCD» |
| Compressor |
exhaust pressure (MPa) |
0.7<0.95>«1.25» |
gas to intake, pressure, temperature (°C) |
air,atmospheric pressure 0 40°C |
air,atmospheric pressure 2 40°C |
air delivery *2 (m3/min) |
8.0<7.0>«6.0» |
| driving system |
gear direct coupling |
| capacity control system |
fine dual control (loaded and unloaded control+back pressure drop+automatic start and stop) |
outlet air temperature (°C) |
intake temp+9°C or less |
intake temp+5°C or less |
air outlet dia. (B) |
1.5 |
lube oil capacity (L) |
17.9 |
noise level *2 (dB(A)) |
64 |
| Main motor |
start-up system |
magnetic star-delta (3 contactors) |
| motor type *4 |
flange horizontal TEFC dust proof, 3 phase, 2 pole, F-class insulation,IP55 Grease suppy system |
motor electric source*3 (kW) |
45 (service factor1.15) |
| Fan motor |
motor type*4 |
TEFC dustproof, 3-phase, 4-pole, F class insulation IP54 |
motor rated output (kW) |
1.0 / 0.98 |
Refrigerated dryer |
outlet air dew point *6 (°C) |
- |
10 or less (under pressure) |
electric consumption (kW) |
- |
2.4/3.0 |
| refrigerant |
- |
HFC404a |
Outer dimensions ((W×L×H)(mm))*7 |
1713×903×1670 |
Mass(with oil) (kg) |
1001 |
1121 |
| *1. |
Air delivery means average air volume discharged under loaded condition 0.7(0.95)«1.25»Mpa converted into atmospheric pressure. |
| *2. |
Noise level means representative figure measured in an anechoic room at 1.0 meter height and 1.5m distance from front at exhaust pressure of 0.7Mpa full-load operation. |
| *4. |
IP55·IP54 means class of dustproof and waterproof performance based on JIS standard. (C4034-5) |
| *5. |
Service factor means service factor (permissible range) of motor. |
| *6. |
Air outlet dew point shows when ambient temperature is 30°C and relative humidity is 70%. |
| *7. |
45 kw is equipped with crank case heater. (Do not shut down breaker since crank case heater is always energized). |
| *8. |
Dimensions show outer dimensions of the package without extruded sections such as valves. |
| *9. |
Please select air receiver capacity of 1500 liters and above. |
| *10. |
As specifications differ between 50Hz and 60Hz, you cannot use it at different Hz site. | | | | |
|
|